PZ30 Patented Type Flush Mount Distribution Box

  • Product Details
  • Related products
Parameter

PZ30 Patent Distribution Box Parameters

Specifications Pcs/Box Panel Size
W*H
Concealed Installation
W*H*D
Surface Mount
W*H*D
6 Ways 20 203*238 170*201*92 178*201*92
8 Ways 20 233*233 206*201*92 214*201*92
10 Ways 10 275*288 242*251*92 249*252*92
12 Ways 10 311*288 278*251*92 285*252*92
15 Ways 10 365*288 332*251*92 339*252*92
18 Ways 10 419*288 386*251*92 393*252*92
20 Ways 10 455*288 422*251*92 429*252*92
24 Ways Single Row 10 528*288 494*251*92 501*252*92
24 Ways Double Row 10 311*458 278*421*92 285*422*92
30 Ways Double Row 5 365*458 332*421*92 339*422*92
36 Ways Double Row 5 419*458 386*421*92 393*422*92
40 Ways Double Row 5 455*458 422*421*92 429*422*92
48 Ways Double Row 5 528*458 494*421*92 501*422*92
45 Ways Triple Row 5 365*628 332*591*92 339*592*92
54 Ways Triple Row 5 419*628 386*591*92 393*592*92
60 Ways Triple Row 5 455*628 422*591*92 429*592*92
72 Ways Triple Row 4 528*628 494*591*92 501*592*92
HOPES FOR A BETTER LIFE
Product Details Display
Bring you a different experience

Large Wiring Space

Large space layout
Ample inner space for circuit breakers. Freer wiring, quick & easy installation.

Double‑Row Copper Terminals

Double row copper wire column
Standard double‑row pure copper terminals. Larger wiring capacity makes field wiring much easier.

Multiple Cable Entry Holes

Multiple wire entry holes
Pre‑punched knock‑out holes on top & bottom. Break out as needed for neat cable routing.

Powder‑Coated Metal Panel

Metal spray panel
Both panel & enclosure adopt electrostatic powder‑coated steel, high rigidity against deformation.

Thickened Steel Plate

Metal spray panel
PZ30 series uses 1.0mm thick steel plate for enhanced structural safety and anti‑deformation performance.
PZ30
Luxury Patented Type
Patented distribution box
1.0mm Galvanized Plate
Terminal Block
Grounding Screw
Multi Entry Holes
Universal Adjuster
Depth AdjustmentLoosen the fixing screws, pull the lifting plate upward to adjust to suitable depth (adjustable range: 30mm)
Left & Right AdjustmentLoosen the fixing screws, slide the plate horizontally to adjust cover level (adjustable range: 15mm)
Up & Down AdjustmentLoosen the fixing screws, shift the plate vertically to align cover height (adjustable range: 6mm)
PZ30 Patent Type
Flush Mount
PZ30 Distribution Box

(PATENTED) UNIVERSAL ADJUSTER

Universal Adjuster
Fixing screw
(left and right)
Rotary drop adjustment screw
Up and down left and
right adjustment shim
Drop adjustment shim

Applicable products:

PZ30、ABC Series
Depth Adjustment

Loosen the fixing screw and pull the " drop adjustment shim " upward, adjusting to the appropriate depth (adjustable range: 30mm).

Left‑Right Adjustment

Loosen the fixing screw, move the " up and down left and right adjustment shim " up and down to the required position (adjustable range: 15mm).

Up‑Down Adjustment

Loosen the fixing screw, move the " up and down left and right adjustment shim " left and right to the required position (adjustable range: 6mm).

Left
Right

The patented universal adjuster must be distinguished between left and right. The left and right cannot be used interchangeably . When installing or replacing later, please distinguish the left and right products.

Complete Application

PRODUCT INSTALLATION GUIDE

Please read the instructions carefully before installation

Surface Mount drawing

Installation Method – (Surface Mount)

Adjustable
mounting
bracket

Flush Mount drawing

Installation Method – (Flush Mount)

Technical Parameters

Standards : IEC 439‑3
Degree of protection : IEC 526 IP41
Rated current : 100 A
Rated operational voltage : 250 V AC 50‑60 Hz
External protection rating : IP41 (IEC529 and GB/T4942‑2)
Terminal specifications : Neutral terminal connection
for copper conductors 25 mm²

Neutral terminal connection
for copper conductors 10 mm²

Ground terminal connection
for copper conductors 16 mm²

Protective conductor terminal
connection for copper conductors 6 mm²

Circuit Breaker Installation

Installing and Removing MCB

Installing the MCB

Removing the MCB

Wiring Diagram Examples

Single‑Phase Wiring (Unsegmented)

Single‑Phase Wiring diagram

Three‑Phase Wiring (Segmented)

Note:
Reserve 2 positions for future use
Three‑Phase Wiring diagram