Contact me immediately if you encounter problems!

Barcha toifalar

PZ30-81 seriyali sirtga o'rnatiladigan taqsimlash qutisi

  • Mahsulotning tafsilotlari
  • Bog'liq mahsulotlar
Parametr

PZ30 bayi seriyasi
Poverxnostniy montazh

Model DONA/DOZA Panel o'lchami
W*H
Sirtga o'rnatiladigan o'lcham
E*B*H
4 Yo'l 60 150*163 149*163*78
6 ta usul 30 186*193 185*193*78
8 yo'nalishli 30 222*193 221*193*78
10 ta usul 30 258*193 257*193*78
12 ta usul 20 294*193 293*193*78
15 usul 15 348*193 347*193*78
18 usul 5 402*193 401*193*78
20 ta yagona qator 15 438*253 437*193*78
24 yo'lli ikki qator 10 294*353 293*353*78
30 yo'lli ikki qator 10 348*353 347*353*78
36 usul ikki qatorli 10 402*353 401*353*78
40 usul ikki qatorli 10 437*353 437*353*78

PZ30 bayi sirtga o'rnatiladigan

Tekis panel, oddiy va zamonaviy

12 ta usul

6 ta usul

4 Yo'l

15 usul

To'rtta amaliy funksiya

O'rnatishdagi qiyinchiliklaringizni osongina hal eting

To'rtta juda amaliy funksiya — o'rnatishdagi muammolaringizni hal qilishni osonlashtiradi

Universal sozlagich

Universal sozlagich

Qopqoqni olib tashlash shart emas, yuqoriga, pastga, chapga va o'ngga sozlanadi

360°

Xavfsizlik himoyasi

360° xavfsizlikni ta'minlash

Uy uskunalari uchun xavfsiz va aqlli boshqaruv

Ko'p yo'nalishli simlar uchun teshiklar

Ko'p yo'nalishli simlar uchun teshiklar

Tez va tartibli simlar ulanishini ta'minlaydigan oldindan mo'ljallangan teshiklar

Ikki qatorli terminal ustunlari

Ikki qatorli mis terminal lar

Osonroq sim ulanishini ta'minlash uchun standart mis terminali

To'liq to'plam qo'llanilishi

Mahsulotning tafsilotlari

MAHSULOTNI O'RNATISH QO'LLANMASI

O'rnatishdan oldin ko'rsatmalarini ehtiyotkorlik bilan o'qing

Surface Mount drawing

O'rnatish usuli – (Sirtga o'rnatish)

Moslashtiriladigan
o'rnatish
bracket

Flush Mount drawing

O'rnatish usuli – (Yopiq o'rnatish)

Texnik parametrlar

Standartlar : IEC 439‑3
Himoya darajasi : IEC 526 IP41
Nominal Tok : 100 A
Ishlash uchun mo'ljallangan nominal kuchlanish : 250 V AC 50‑60 Gs
Tashqi himoya darajasi : IP41 (IEC529 va GB/T4942‑2)
Terminal parametrlari : Neytral terminal ulanishi
mis o'tkazgichlar uchun 25 mm²

Neytral terminal ulanishi
10 mm² mis o'tkazgichlar uchun

Yerlangan terminal ulanishi
16 mm² mis o'tkazgichlar uchun

Himoya o'tkazgichi terminali
6 mm² mis o'tkazgichlar uchun ulanish

Avtomatik qurilma o'rnatilishi

Installing and Removing MCB

MCB ni o'rnatish

MCB ni olib tashlash

Ulanish sxemalari namunalari

Bir fazali ulanish (bo'linmagan)

Single‑Phase Wiring diagram

Uch fazali ulanish (bo'lingan)

Eslatma:
Kelajakda foydalanish uchun 2 o'rinni band qilish
Three‑Phase Wiring diagram

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000